Pengertian, Fungsi Dan Macam-macam Alat Kesehatan Lingkungan
Pengertian alat kesehatan lingkungan
Fungsi alat kesehatan lingkungan
Macam-macam alat kesehatan lingkungan
1. ATP Bacteria Meter Analyzer – HD-420 Biobase
- Cepat: kultur konvensional 18-24 jam di atas, sedangkan ATP hanya membutuhkan waktu sepuluh detik.
- Kelayakan:Dengan mendeteksi kandungan ATP, jumlah mikroorganisme dalam reaksi dapat diperoleh secara tidak langsung.
- Operabilitas:Metode budidaya tradisional perlu dilakukan oleh teknisi terlatih di laboratorium.
Model | BKHD-420 |
Detection Accuracy | 5x10-18mol |
Coliform Bacteria | 1-106cfu |
Detection Rang | 0 -9999 RLUs |
Detection Time | 5 seconds |
Test Interference | ±5% or±5 RLUs |
Operating Temperature Range | 5 - 40 ° C |
Operating Humidity Range | 20-85% |
ATP Recovery Rate | 90% -110% |
Package Size (W*D*H)mm | 240x180x100 |
Net Weight(kg) | 0.5 |
Gross Weight(kg) | 0.65 |
Velocity VEL
(RMS, PEAK, MAX HOLD) |
|||
Range |
0.5~199.9mm/s |
0.05~19.99 cm/s |
0.02~7.87 inch/s |
Resolution |
0.1 mm/s |
0.01cm/s |
0.01 inch/s |
Accuracy |
± (5%+5d) @79.4Hz
and 158Hz |
± (5%+5d) @79.4Hz
and 158Hz |
± (5%+5d) @79.4Hz
and 158Hz |
Calibration point |
50m/s (158Hz) |
50m/s (158Hz) |
50m/s (158Hz) |
Displacement DISP
(P-P, MAX HOLD P-P) |
||
Unit |
mm |
inch |
Range |
0.005~1.999 mm |
0.002~0.078 inch |
Resolution |
0.001 mm |
0.001 inch |
Degree of error |
± (5%+5d)@79.4Hz and 158Hz |
± (5%+5d)@79.4Hz and 158Hz |
Calibration point |
0.141mm (158Hz) |
0.141mm (158Hz) |
Pocket scale |
Curcumin
paper |
1 x 10 ml
cell, 1 x Stirring rod |
Gelas beaker 50
ml |
Mortar + Pestle |
1 Discs &
tablets |
Pipet plastik 1
ml |
Batang pengaduk dari kaca |
Tas alat |
Syringe 5 ml |
Washing Bottle
250 ml |
Buku manual
bahasa Indonesia |
Sarung tangan
bedah |
65 ml PL Fluoride 1 Solution |
|
Cotton masker |
65 ml PL Fluoride
2 Solution |
Parameter |
Range |
Quantity |
Suhu |
-40 ~ +250 °C |
1 unit |
Boraks |
0 – 10.000 mg/l |
100 test |
Formalin |
0 – 200 mg/l |
100 test |
Rhodamin B |
0 – 40 mg/l |
100 test |
Arsenik |
0 – 3.0 mg/l |
100 test |
Fluorida |
0 – 2.00 mg/l |
100 test |
Merkuri |
0 – 3000mg/l |
100 test |
Methyl Yellow |
0 – 50 mg/l |
100 test |
Plumbum / Lead |
20 – 500 mg/l |
100 test |
Sianida |
0 – 0.20 mg/l |
100 test |
Siklamat |
reagent standards |
100 test |
Sakarin |
reagent standards |
100 test |
Benzoat |
reagent standards |
100 test |
Uji Bangkai Ayam |
qualitative +/- (positive jika
berwarna hijau) |
150 test |
3. ENVILIFE SAN-01 Sanitarian Kit
Suhu |
|
Measurement range |
-40 ~ 70°C (-40 -
158°F) |
Accuracy |
±2.0°C (±3.6°F) |
Measurement units |
°C (°F) |
Resolution |
0.1 |
Kelembapan |
|
Measurement range |
10 - 95%RH |
Accuracy |
±5RH%55mm |
Resolution |
0.1 |
Pencahayaan |
|
Measuring range |
0 Lux - 200K Lux, 0Fc - 20KFc |
Spectral accuracy |
CIE V and λ
function f1’≦6% |
Cosine response |
f2’≦2% |
Accuracy |
±4% rdg ±0.5%f.s.
(<10,000Lux) |
±5% rdg ±10dgts. (>10,000Lux) |
|
Kebisingan |
|
Accuracy |
±2.0dB |
Resolution |
0.1dB |
Frequency
response |
31.5Hz - 8kHz |
Measurement range |
Auto 35dB - 130dB |
Air velocity |
|
Range |
0.5m/s - 30.0m/s |
Accuracy |
±3% |
Pengukuran
Partikulat di udara |
|
PM Sensor |
Laser Scattering |
HCHO Sensor |
Electrochemistry
sensor |
TVOC Sensor |
Semiconductor sensor |
Detection range |
AQI(0-500) |
HCHO(0.001-1.999Mg/M³) |
|
TVOC(0.001-9.999Mg/M³) |
- E-Coli (koli tinja) : 48 Sampel
- Coliform : 48 Sampel
- Temperature range : -50°C~300°C(-58°F~572°F)
- Temperature accuracy : 1°C (1.8°F)
- Temperature resolution : 1°C (0.2°F)
- pH Range: 0.00 to 14.00 pH
- EC Range: 0.00 to 6.00 mS/cm
- TDS Range: 0 to 4000 ppm
- pH Resolution: 0.1 pH
- EC Resolution: 0.01 mS/cm
- TDS Resolution: 10 ppm
- pH Accuracy: ±0.2
- EC/TDS Accuracy: ±2% Full Scale
- Calibration Solutions: M10007 (pH 7.01) M10032 (1382 ppm) M10442B 1500 ppm
- Range : 0 ~ 19.99 NTU, 20.0 ~ 199.9 NTU, 200 ~ 1000 NTU
- Resolution : 0.01/0.1/1 NTU
- Accuracy : ± 3% reading + 1 digit at < 500 NTU, ± 5% reading + 1 digit at > 500 NTU
- Operating : 0 ~ 50 °C, <85% RH
- pH Range : 00 to 14.00 pH = 50 sampel
- EC Range : 00 to 6.00 mS/cm = 50 sampel
- TDS Range : 0 to 4000 ppm = 50 sampel
- pH Resolution : 1 pH = 50 sampel
- EC Resolution : 01 mS/cm = 50 sampel
- TDS Resolution : 10 ppm = 50 sampel
- pH Accuracy : ±0.2 = 50 sampel
- EC/TDS Accuracy : ±2% Full Scale = 50 sampel
- Calibration Solutions : M10007 (pH 01), M10032 (1382 ppm), M10442B 1500 ppm = 50 sampel
Alkalinity(NO2) |
: 5 - 500 mg/L
CaCO |
Manganese |
: 0.2 - 4 mg/L Mn |
Alkalinity(NO3) |
: 5 - 300 mg/L
CaCO3 |
Molybdenate/Molybdenum |
: 1 - 50 mg/L Mo4 |
Aluminium |
: 0.01 - 0.3 mg/L Al |
Monochloramine |
: 0.04 - 4.5 mg/L Cl2 |
Ammonia |
: 0.02 - 1 mg/L N |
Nickel |
: 0.1 - 10 mg/L
Ni |
Boron |
: 0.1 - 2 mg/L B |
Nitrate |
: 0.08 - 1 mg/L N |
Bromine |
: 0.05 - 13 mg/L
Br |
Nitrite |
: 0.01 - 0.5 mg/L
N |
Chloride |
: 0.5 - 25 mg/L Cl- |
Oxygen, active |
: 0.1 - 10 mg/L O2 |
Chlorine |
: 0.01 - 10 mg/L
Cl2 |
Ozone |
: 0.02 - 2 mg/L
O3 |
Chlorine Dioxide |
: 0.02 - 11 mg/L ClO2 |
pH-value |
: 5.2 - 9.6 pH |
Chromium |
: 0.02 - 2 mg/L
Cr |
Phosphate |
: 0.02 - 100 mg/L
Po4 |
COD |
: 0 - 15000 mg/L O2 |
Potassium |
: 0.7 - 12 mg/L K |
Copper |
: 0.05 - 5 mg/L
Cu |
Silica |
: 0.05 - 90 mg/L
SiO2 |
Copper, free |
: 0.05 - 5 mg/L Cu |
Sodium hypochlorite |
: 0.2 - 16 % NaOCl |
Cyanide |
: 0.01 - 0.5 mg/L
CN |
Sulfate |
: 5 - 100 mg/L
So4 |
Cyanuric acid |
: 0 - 160 mg/l CyS |
Sulfide |
: 0.04 - 0.5 mg/L S |
Fluoride |
: 0.05 - 2 mg/l F |
Sulfite |
: 0.1 - 5 mg/L
So3 |
Hardness, calcium |
: 0 - 900 mg/l CaCO3 |
Suspended Solids |
: 5 - 750 mg/L |
Hardness, total |
: 2 - 500 mg/L
CaCO3 |
Turbidity
(attenuated radiation method) |
: 0 - 1000 NTU |
Hazen |
: 0 - 500 mg/L Pt-Co-units |
Urea |
: 0.1 - 2.5 mg/L CH4N2O |
Hydrazine |
: 0.05 - 0.5 mg/L
N2H4 |
Zinc |
: 0.02 - 1 mg/L
Zn |
Hydrogen Peroxide |
: 0.03 - 3 mg/L H2O2 |
||
Iodine |
: 0.05 - 3.6 mg/L
I |
||
Iron (Fe2+, |
: 0.02 - 3 mg/L Fe Fe3+, soluble) |
- Capacity : 5L
- range : RT +5 – 50°C
- Accuracy : 0.2°C
- Timing : 0-9999min
- Voltage : 220V/ 50Hzunit
- Power : 300W
- Inner Chamber size (mm) : 230x200x160
- Exterior size (mm) : 300x330x330
4. LABOSTAR Pro TWF UV Water Purification System
- Sensor konduktivitas secara konstan mengukur kemurnian air produk dalam loop resirkulasi.
- Filter steril 0,2 m bermuatan positif di dispenser menghilangkan bakteri dan endotoksin, menghilangkan kebutuhan akan ultrafilter yang mahal.
- Filter steril 0,2 m tanpa muatan juga tersedia.
- LABOSTAR Pro TWF UV Water Purification System dikirimkan dengan set modul dan filter pertama.
- Micro- und molecular biology
- PCR
- HPLC
- TOC analysis
- Type III water
Type III water specifications |
|
Flow rate @25ºC |
13 l/h |
Flow rate @20ºC |
11 l/h |
Flow rate @15ºC |
10 l/h |
Rejection rate for ions |
98% max |
Rejection rate for bacteria |
>98% |
Rejection rate for particles |
>98% |
Type I water specifications |
|
Output up to |
1,2/min |
Conductivity @25ºC |
0,055 µS/cm |
Resistivity @25ºC |
18,2 MΩ-cm |
TOC |
1-5 ppb |
Bacteria |
<1 cfu/ml |
Endotoxins |
<0,001 EU/ml |
Particles > 0.2 µm |
<1 per ml |
Feed water specifications |
|
Pressure |
3-5 bar |
Conductivity |
<2000 µS/cm |
Colloid Index |
<3 SDI |
Free Chlorine |
<0,5 mg/l |
Fe |
<0,1 mg/l |
Co²max |
<15 mg/l |
Water temperature |
5-30ºC |
Ambient temperature |
5-35ºC |
Connections |
|
Raw water |
5/16” push-in / flex tube |
Pure water |
¼” push-in / flex tube |
Drain concentrate |
3/8” push-in / flex tube |
Power requirement |
|
Power consumption |
270 W |
Power supply |
100-240V / 50-60Hz |
Dimensions |
535x400x520 mm |
Catalogue number |
W3T324338 |
INCLUDE |
|
W3T324494 (30 L Storage tank
for Labostar Pro TMF |
|
Module 2057 (Pre-treatment
module) AMB W3T197613 |
|
Module 2094 (Pre-treatment
module DTO) W3T197613 |
|
Module 2051 (Polishing Module
MFIIID) W3T197694 |
|
Tank ventilation sterile filter
3-pack) W3T199880 |
|
Dispenser sterile filter (0.2
µm positively charged) W2T526015 |